7
SoundPlus
®
Infrared Listening System
MAN 132H
Conguration Settings
Figure 8 illustrates how to congure your system using the DIP switches (Figure 7) located on the back of the MOD
232 Modulator. This diagram is also printed on top of the MOD 232 Modulator unit for quick reference.
A250
CHANNEL A AND B
CONFIGUREATION
SWITCHES
A252
Figure 8: DIP Switch Conguration Chart
IMPORTANT: Channel A and Channel B must be set to different frequencies!
Compressor Gain
The MOD 232’s Compressor Gain is set in “Moderate” mode from the factory. Use this setting for simultaneous
interpretation. Be sure that the compress control, located on the front of the MOD 232 (Figure 6, page 6), is turned
fully counter-clockwise. Compression can be added if desired by turning the compress control clockwise.
For hearing assistance applications, the MOD 232’s Compressor Gain can be set to “Maximum” mode. For additional
compression, use a tuning wand (PLT 005) or small screw driver and gently turn the compress control (Figure 6, page
6) on the front of the MOD 232 clockwise.